CLIMAT Serie PF-Z
-
Diathermic oil 250°C
-
Single/Twin zone
-
Electric external elements (IHCS system)
-
Magnet driven pumps
PF Z 250 single or twin zone is a hydraulic-electric unit designed to regulate die temperatures by diathermic oil driven into the conditioning channels and heated by EXTERNAL RESISTORS (IHCS system, IECI patent). The real advantage is given by the electric element long lasting life and by the limitation of oil cracking caused by heat.
It is an open system with a tank of adequate size to contain the oil increased volume due to temperature raise. Maximum thermal-vector fluid temperature is 250°C, while minimum temperature is determined by water mains parameters (pressure, flow, temperature) connected to the heat regulators.
|
TECHNICAL DATA |
|
Number of zone |
1 |
2 |
|
Code |
CCPZ003 |
CCPZ010 |
|
Frame |
T1 500x1300x1230 (h) |
T1 500x1300x1230 (h) |
|
Weight |
180 Kg |
370 Kg |
|
Maximum temperature |
250°C |
|
Circuit fluid |
Diathermic oil |
|
Heating system |
external electric resistors. |
|
Maximum heating power |
24 Kw |
|
Cooling system |
indirect exchange |
|
Cooling power |
60,000 Kcal/h (with water at 25°C and oil at 200°C) |
|
Electric pump |
external magnet driven |
|
Max. flow rate of pump |
60 lt/min |
|
Max. pump pressure |
6 bar |
|
Pump power |
1,1 Kw |
|
Fluid loading in circuit |
manual |
|
Power supply |
400 V+PE, auxiliaries 24 VAC |
|
Water supply |
raccordo ½" |
|
Die connections |
1/2 “ connector |
|
Tank |
Stainless-steel 20 LT |